Abstract

This analysis aimed to identify clinical factors associated with positivity on repeat 68Ga-PSMA-11 PET/CT after a negative scan in patients with recurrent prostate cancer (PCa) under observation. Methods: This single-center, retrospective analysis included patients who underwent at least 2 68Ga-PSMA-11 PET/CT scans (PET1 and PET2) at UCLA between October 2016 and June 2021 for recurrent PCa with negative PET1 and no PCa-related treatments between the 2 scans. Using Prostate Cancer Molecular Imaging Standardized Evaluation criteria to define negative and positive scans, the final cohort was divided into PET2-negative (PET2-Neg) and PET2-positive (PET2-Pos). The same PET1 was used twice in the more than 2 PET cases with inclusion criteria fulfilled. Patient characteristics and clinical parameters were compared between the 2 cohorts using Mann-Whitney U test and Fisher exact test. Areas under the curve (AUCs) of the receiver operating characteristic and the Youden index were computed to determine the discrimination ability of statistically significant factors and specific cut points that maximized sensitivity and specificity, respectively. Results: The final analysis included 83 sets of 2 PET/CT scans from 70 patients. Thirty-nine of 83 (47%) sets were PET2-Neg, and 44 of 83 (53%) sets were PET2-Pos. Prostate-specific antigen (PSA) increased from PET1 to PET2 for all 83 (100%) sets of scans. Median PSA at PET1 was 0.4 ng/mL (interquartile range, 0.2-1.0) and at PET2 was 1.6 ng/mL (interquartile range, 0.9-3.8). We found higher serum PSA at PET2 (median, 1.8 vs. 1.1 ng/mL; P = 0.015), absolute PSA difference (median, 1.4 vs. 0.7 ng/mL; P = 0.006), percentage of PSA change (median, +270.4% vs. +150.0%: P = 0.031), and median PSA velocity (0.044 vs. 0.017 ng/mL/wk, P = 0.002) and shorter PSA doubling time (DT; median, 5.1 vs. 8.3 mo; P = 0.006) in the PET2-Pos cohort than in the PET2-Neg cohort. Receiver operating characteristic curves showed cutoffs for PSA at PET2 of 4.80 ng/mL (sensitivity, 34%; specificity, 92%; AUC, 0.66), absolute PSA difference of 0.95 ng/mL (sensitivity, 62%; specificity, 71%; AUC, 0.68), percentage of PSA change of a positive 289.50% (sensitivity, 48%; specificity, 82%; AUC, 0.64), PSA velocity of 0.033 ng/mL/wk (sensitivity, 57%; specificity, 80%; AUC, 0.70), and PSA DT of 7.91 mo (sensitivity, 71%; specificity, 62%; AUC, 0.67). Conclusion: Patients with recurrent PCa under observation after a negative 68Ga-PSMA-11 PET/CT scan with markedly elevated serum PSA levels and shorter PSA DT are more likely to have positive findings on repeat 68Ga-PSMA-11 PET/CT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.