Abstract

Introduction: Central venous catheters are vital in critical care which can be associated with infectious and non-infectious adverse events. Materials and Methods: This case–control study was conducted over 1 year in trauma centre of India. All patients admitted in intensive care units (ICUs) having central line inserted during the study period (November 2013–October 2014) were included as cases. Historical controls with non-antibiotic-impregnated dressings were used as controls (November 2012–October 2013). Standard central line insertion and maintenance checklist was followed. Results: A total of 2034 patients were admitted in ICUs during study period, and the central line-associated bloodstream infection (CLABSI) rate was 2.89/1000 catheter days. During the year 2012–2013, 2100 patients were admitted and CLABSI rate was 3.04/1000 catheter days. The mean central line insertion bundle compliance rate was 76.8% in 2012–2013 and 78.37% in 2013–2014. The compliance with scrubbing the access port was minimum 34% while that with change in dressing was the maximum 79%. Discussion: Since CLABSI rate reduction was not statistically significant, the use of biopatch in our setting could not be justified and its use was not found to be cost-effective. In maintenance bundle, compliance with scrubbing the hub was least only 35%. Thus, the use of effective maintenance bundle parameters could easily reduce CLABSI rate.