Abstract

To test whether implants placed with simultaneous guided bone regeneration (GBR) differ from implants placed without GBR regarding survival rate, interproximal marginal bone level (MBL), and dimensions of buccal bone and mucosa. Twenty-three patients treated 15years earlier were included. Machined implants had been inserted following one of the two procedures: (i) with simultaneous GBR, which involved grafting with particulate deproteinized bovine bone mineral (DBBM), autogenous bone (AB), or a mixture of the two and defect covering with a native collagen membrane (CM) (GBR group) and (ii) standard implant placement without GBR (control group). One GBR and one control implant in each patient were selected for analysis. At 15years, the dimensions of buccal bone and mucosa were measured with cone beam computed tomography. The interproximal MBL was evaluated at 5 and 15years on periapical radiographs. The 15-year survival rate amounted to 95.6% for GBR implants and to 94.1% for control implants. At 15years, interproximal MBL measured 1.44±0.84mm for the GBR group and 1.69±0.84mm for the control group. From the 5- to the 15-year examination, the loss of interproximal MBL reached 0.23±0.70mm for the GBR group and 0.28±0.63mm for the control group. At 15years, buccal MBL measured 1.98±0.98mm for GBR implants and 2.19±1.29mm for control implants. None of these values reached statistical significant differences between the groups. In cases in which GBR involved grafting with DBBM, GBR implants achieved approximately 0.3-0.4mm higher mean values in buccal bone dimensions and mucosal level in comparison to control implants. In contrast, when GBR was performed by grafting with AB without DBBM, implants rendered less favourable results in buccal bone and mucosa dimensions than the control implants. Implants placed with simultaneous GBR using particulate DBBM and/or AB in combination with CM did not significantly differ from implants completely placed into pristine bone with respect to 15-year implant survival, interproximal bone levels, and dimensions of buccal bone and mucosa. The machined-surface implants placed both into native bone and sites augmented by GBR exhibited stable interproximal bone levels.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call