Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background. Delirium is frequent in patients admitted to critical care units. Its incidence after transcatheter aortic valve implantation (TAVI) is up to 30%. Clinical and demographic factors have been related to delirium, but echocardiographic parameters have not been evaluated. Purpose. The aim of this study was to assess clinical and echocardiographic predictors of delirium in patients admitted to an acute cardiac care unit (ACCU) after transfemoral TAVI. Methods. 501 patients admitted to ACCU after TAVI were included. Delirium was evaluated by Confusion Assessment Method. Clinical cardiovascular and geriatric conditions were assessed, as well as echocardiographic parameters. Results. The incidence of delirium was 22% (110 patients). Delirium was associated with age (83.8 ± 4.6 vs 82.6 ± 6.1 years, p = 0.026), dyslipidaemia (50.0% vs 61.4%, p = 0.032), prior peripheral arterial disease (11.9% vs 5.4%, p = 0.017) and cognitive impairment (10.0% vs 1.8%, p < 0.001). There was no relationship to gender, other cardiovascular risk factors or geriatric conditions. Table shows echocardiographic parameters at baseline and after TAVI, with no statistical association with delirium. Conclusion. Delirium is a common complication after TAVI in ACCU. Age, the absence of dyslipidaemia, or the presence of cognitive impairment or prior peripheral arterial disease are clinical predictors of delirium. There are not echocardiographic predictors of delirium. Echocardiographic parametersWithout delirium(n = 391)With delirium(n = 110)p valueBaseline echocardiographic parametersLeft ventricular ejection fraction (%)57.7 ± 13.457.5 ± 14.10.912Mitral regurgitation (moderate to severe)106 (27.1)34 (30.9)0.433Pulmonary hypertension168 (43.0)53 (49.1)0.258Aortic regurgitation (moderate to severe)74 (18.9)21 (19.1)0.969Peak aortic gradient (mmHg)78.7 ± 25.278.5 ± 23.30.935Mean aortic gradient (mmHg)47.1 ± 16.146.7 ± 14.80.838Aortic valvular area (cm2)0.6 ± 0.20.6 ± 0.20.589Aortic annulus diameter (mm)22.5 ± 2.722.4 ± 2.50.615After TAVI echocardiographic parametersAortic regurgitation (moderate to severe)36 (9.3)11 (10.0)0.813Peak aortic gradient (mmHg)17.6 ± 9.617.7 ± 8.30.916Mean aortic gradient (mmHg)8.9 ± 5.49.3 ± 4.90.481Aortic valvular area (cm2)2.0 ± 0.62.2 ± 0.60.478Values are mean ± standard deviation, or n (%).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call