Abstract

Space-division multiplexing (SDM) attracts attention to cladding-pumped optical amplifiers, but they suffer from a low pump power conversion efficiency. To address this issue, ytterbium (Yb3+) and erbium (Er3+) co-doping is considered as an effective approach. However, it changes the gain profile of Er3+-doped fiber amplifiers and induces the gain difference between optical wavelengths in the C-band, significantly limiting the effective band of the dense wavelength-division multiplexed (DWDM) system. This paper is devoted to a detailed study of a cladding-pumped Er3+/Yb3+ co-doped fiber amplifier (EYDFA) through numerical simulations aiming to identify a configuration, before assembling a similar EYDFA in our laboratory premises that ensures the desired performance. The simulation model is based on a commercial double cladding EYDF whose parameters are experimentally extracted and fed to the EYDFA setup for the system-level studies. We investigate the wavelength dependence of the amplifier’s characteristics (absolute gain, gain uniformity, noise figure) and bit error rate (BER) performance for several DWDM channels and their optical power. The obtained results show that a 7 m long EYDF and co-propagating pump direction is preferable for the EYDFA with a 3 W pump source at 975 nm and with the given gain medium characteristics for WDM applications. For instance, it ensures a gain of 19.7–28.3 dB and a noise figure of 3.7–4.2 dB when amplifying 40 DWDM channels with the input power of −20 dBm per channel. Besides, we study EYDFA gain bandwidth and the maximum output power when operating close to the saturation regime and perform a sensitivity analysis showing how the doped fiber’s absorption and emission cross-sections impact the amplification process through energy transfer from Yb3+ to Er3+. Finally, we quantify the power penalty introduced by the EYDFA; the results show that it is not higher than 0.1 dB when amplifying 40 × 10 Gbps non-return-to-zero on-off keying signals from −20 dBm/channel.

Highlights

  • An immerse variety and accessibility of multimedia services, such as Netflix, YouTube, etc., together with optical fiber penetration in rural areas and growing numbers of end users, have caused a tremendous increase in internet traffic that must be supported by telecom infrastructure [1,2]

  • Considering these aspects of growth rates of internet traffic, the versatility of broadband and multimedia services, as well as cost and energy efficiencies, space-division multiplexing (SDM) is considered as one of the biggest breakthroughs in fiber-optic communications able to support the sustainable evolvement of telecom networks and services [3,4,5]

  • The results show that, for the considered scenario, the maximum transmission distance decreases from 11 spans to only eight spans when replacing the conventional inline EDFAs (NF = 4.5 dB)

Read more

Summary

Introduction

An immerse variety and accessibility of multimedia services, such as Netflix, YouTube, etc., together with optical fiber penetration in rural areas and growing numbers of end users, have caused a tremendous increase in internet traffic that must be supported by telecom infrastructure [1,2]. As the COVID-19 pandemic has shown, both telecom infrastructure providers and service providers get entrusted with a role of technological pillars, bonding humanity and supporting our society and business in daily activities such as remote work and distance education Considering these aspects of growth rates of internet traffic, the versatility of broadband and multimedia services, as well as cost and energy efficiencies, space-division multiplexing (SDM) is considered as one of the biggest breakthroughs in fiber-optic communications able to support the sustainable evolvement of telecom networks and services [3,4,5]. To ensure cost-efficient optical signal amplification in SDM-based fiber-optic transmission systems, cladding-pumped doped fiber amplifiers (DFAs) have attracted increased attention They are considered as one of the most suitable amplification approaches from the perspective of both capital expenditure (CAPEX) and operational expenditure (OPEX) [6]. The use of only one pumping source improves the cost-efficiency, helps to reduce the size of a multicore amplifier, and saves physical space in a rack when migrating to such an amplifier implementation [2]

Methods
Results
Conclusion