Abstract
In the work an approach to avoid a circumferential temperature distribution existing during nucleate pool boiling on a horizontal cylinder within low heat flux densities is presented. The idea of the approach is local heat transfer enhancement by a porous layer application on a part of the heating surface. An experiment on nucleate pool boiling heat transfer from horizontal cylinders to saturated R141b and water under atmospheric pressure is reported. Experiments have been conducted using stainless steel tubes with the outside diameter between 8 mm and 23 mm with the active length of 250 mm. The outside surface of the tubes was smooth or partially coated with a porous metallic layer. In particular, measurements of inside circumferential temperature distribution have been performed.