Abstract
Abstract Steady-state and transient critical heat flux (CHF) experiments were performed using triangular pitched 7-rod assemblies with non-uniform axial power distributions under the maximum pressure of 15.5 MPa. The onset of steady-state CHF was predicted within the uncertainty of 10% with the KfK correlation using the local flow conditions calculated by the subchannel analysis code COBRA-IV-T. On the other hand, various mechanistic CHF models did not agree with the steady-state CHF data. The transient CHFs under the conditions of flow reduction, power increase or flow and power simultaneous variation were predicted with the quasi-steady-state method within approximately the same uncertainty as the steady-state CHF experiments. The predictive capability did not depend on the transient speed within 30%/s of the flow reduction rate and within 120%/s of the power increase rate. It was also revealed that there exists large CHF margins under the thermal hydraulic conditions simulating the locked rotor accident and the control rod cluster ejection accident of the double-flat-core type high conversion pressurized water reactor (HCPWR).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.