Abstract

In steam generating systems, the concentration of solutes in contact with heat transfer surfaces, a decisive factor in determining the actual material corrosive environment, exceeds that of the bulk fluid. The ratio of the local to bulk concentration can vary from a factor of less than ten for normal boiling on clean surfaces to five or six orders of magnitude under dryout conditions. The literature of this important technological question is reviewed and the various models that have been proposed to explain and predict the concentration process are examined in terms of chemical and thermohydraulic fundamentals. The concentration process in thin porous deposits at high heat fluxes is still unresolved

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.