Abstract

A standard Fricke dosimeter was used to measure the absorbed dose via the oxidation yields of Fe3+ ions in an aqueous environment induced by soft X rays within the "water window" spectral range. We also exploited the property of a neutral solution containing terephthalic acid as a tool for selective detection of OH radicals. Both dosimetric systems were irradiated using the experimental pulsed laser-plasma soft X-ray source as well as conventional 1.25-MeV gamma rays. Radiation chemical yields of Fe3+ ions and OH radicals were determined to be (5.13 ± 0.94) × 10-1 µmol·J-1 (4.95 ± 0.91 100eV-1) and (2.33 ± 0.35) × 10-2 µmol·J-1 (0.23 ± 0.03 100eV-1), respectively. Measurements were supported by Monte Carlo simulations to estimate the linear energy transfer of the water window radiation. The simulation results are in good agreement with expected linear energy transfer of ions inducing the same Fe3+ ion and OH radical radiation chemical yield.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.