Abstract
This research was carried out to evaluate the effects of different dosages (1.85–4.44 g kg−1 Ts−1) of three cationic polyelectrolytes with charge densities (CD) of 20%, 40%, and 60% on the dewatering properties of an aerobically digested sludge. The sludge was collected from the sludge processing line in a wastewater treatment plant in the city of Mashhad, Iran (MWWTP). To assess the sludge dewatering properties, parameters such as specific resistance to filtration, sludge cluster geometry, filtration rate, and filtrate turbidity and volume were measured. The experimental results were then compared with the effects of a reference polyelectrolyte that was used in the conditioning of the sludge in that treatment plant. The results indicated that the sludge samples treated with the polyelectrolyte of the highest CD matched better dewatering performance than the samples conditioned with the other two polyelectrolytes. This polyelectrolyte (60%CD) presented its best effects at the dosage of 4.07 g kg−1 Ts−1. With this dosage, its performance was similar to the performance of the reference polyelectrolyte at the dosage of 4.44 g kg−1 Ts−1.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.