Abstract

Maximum pressure head rises, which result from valve closure according to (a) uniform, (b) equal-percentage, and (c) optimum valve closure arrangements, are calculated and plotted for the valve end and for the midpoint of a simple pipeline. Basic parameters such as the pipeline constant, relative closure time, and pipe wall friction are considered for closures both from partial as well as from full valve openings. The results of this paper can be used to draw the maximum hydraulic grade line along the pipe for these closure arrangements. It is found that the equal-percentage closure arrangement yields consistently less pressure head rise than does the uniform closure arrangement. Further, the optimum closure arrangement yields consistently less head rise than the equal-percentage one. Closures from partial valve openings increase the pressure head rise considerably and must always be considered.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.