Abstract

Maximum pressure head rises resulting from water column separation and check valve closure are calculated and plotted for a simple low head pump discharge line with one well-defined high point. Basic parameters such as pipeline constant, pipe wall friction, complete pump characteristics, pump inertia constant, and the relative location of the high point are accounted for in the analyses. The results of this paper can be used to determine (a) when water column separation is expected, (b) how to avoid water column separation, and (c) the necessary wall thickness in cases where no protection against water column separation is provided. Computer studies indicate that both the vertical and horizontal location of the high point as well as the pipe friction, the pipeline constant, and the pump inertia have a major effect on pressure head rises. Water column separation does not always constitute a danger to the pipeline. Key words: waterhammer, water column separation, check valve closure, pressure rise, pump discharge line, chart.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.