Abstract

Charging phenomena is one of the main problems faced in ion implantation. Anti-charging system such as plasma flood gun (PFG) are currently running on high current and medium current implanters to reduce potential charging damage on device structures. However, in a conventional production line, high energy implantation steps are still often used without any charge compensation technique. Faced with micro-arcing defects detected after Well implantation steps on production lots, we have clearly demonstrated that the defectivity issue was eradicated by enabling the PFG system on the VIISta3000 high energy implanter. In addition we have investigated charging as a function of PFG properties by plasma damage monitoring (PDM) and proved that voltages developed on oxidized wafers processed on the VIISta3000 were not insignificant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.