Abstract

Semiconductor detectors based on natural diamonds have been installed on the Large Helical Device (LHD) heliotron to measure the energy distribution of charge exchange fast neutral particles from different viewing angles. Advantages of a natural diamond detector (NDD) are (1) very compact size, (2) relatively easy handling, and (3) high energy resolution. Although NDDs are sensitive to visible light, vacuum ultraviolet, and soft x rays, unfavorable pulses produced by such radiation were greatly reduced by choosing an appropriate stainless steel shield in this experiment. In LHD, the time-resolved energy distribution of counter-going beam ions and ion cyclotron range of frequency-produced energetic ions have been successfully obtained by means of an NDD. The performance of NDDs as a neutral particle analyzer and its good suitability to LHD plasmas were demonstrated throughout this work.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.