Abstract
Megasonic cleaning is routinely used for removal of particulate contaminants from various surfaces in integrated circuit industry. One of the drawbacks of megasonic cleaning is that although it can achieve good particle removal efficiencies at high power densities, it also causes feature damage. The current paradigm is that damage is primarily caused by transient cavitation whereas cleaning is affected by streaming and stable cavitation. In order to develop a damage-free and effective megasonic cleaning process, it is essential to understand the acoustic bubble behavior and identify conditions that generate significant stable cavitation without any transient cavitation. In the current work, microelectrode based chronoamperometry, pressure measurements using a hydrophone and fluorescence spectroscopy studies were conducted under different acoustic frequencies (1–3MHz) and power densities (2–8W/cm2) to fundamentally investigate the type of cavitation produced under these conditions and also establish a correlation to the generation of hydroxyl radicals for characterization of transient cavitation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.