Abstract

Using low-angle laser light-scattering (LALLS) and multiangle laser light-scattering (MALLS) techniques, absolute molar mass averages were determined for a wide variety of polymers in the Methocel™ product line produced by The Dow Chemical Company. These data were correlated to GPC molar mass averages obtained from column calibration using pullulan standards. It was determined that the pullulan equivalent molar mass averages overestimated the values determined by light scattering by a factor as high as 3.2. Mark-Houwink parameters were calculated based upon values for the pullulan standards and application of the universal calibration concept. Sample preparation issues and chromatographic conditions that impact data quality are also presented. © 1998 John Wiley & Sons, Inc. J Appl Polym Sci 70: 2197–2210, 1998

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.