Abstract

Objective Lack of biomimicry in geometry and flow conditions of emissions systems for analytical testing and biological exposure has led to fundamental limitations, including a poor understanding of dose delivered to specific airway locations. This work characterizes mass distribution of a JUUL® brand e-cigarette in a Biomimetic Aerosol Exposure System (BAES). Materials and Methods A combination of mass balance, direct measurements, and inferences based on direct measurements were used to characterize regional and local dose as a function of system flow path configuration and emissions topography profile. Results Doses produced by the emissions topography profile with only puffing were significantly different from profiles with clean air inhalation following puffs. Mass characterization results support that dose can be manipulated using flow path geometry. Local and regional deposition was mapped throughout the system. Discussion and Conclusions We estimate the fraction of yield to the mouth deposited at several locations throughout the system for a variety of puffing and respiration topographies and show that emissions topography profile and system flow path geometry affect dose. This work provides proof-of-concept for assessing mass distribution as a function of aerosol generator (e-cigarette product), user airway geometry, and inhalation and puffing topography.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call