Abstract

Cathode ray tubes (CRTs) in television and computer monitors are one of the most common components of discarded electronics in the solid waste stream. CRTs present a disposal problem because of their growing magnitude in municipal solid waste (MSW) and their role as a major source of lead in MSW. Using the EPA Toxicity Characteristic Leaching Procedure (TCLP), lead leachability from CRTs was studied. Lead leached from the CRT samples at an average concentration of 18.5 mg/L. This exceeded the regulatory limit of 5.0 mg/L. Several factors affected the lead concentrations of each CRT sample. These included the sample fraction of the CRTs, the particle size used in the tests, and the CRT type. The most significant quantities of lead were obtained from the funnel portion of the CRTs at an average lead concentration of 75.3 mg/L. The major source of lead in the funnel is the frit seal of color CRTs. Samples containing the frit seal had lead leaching levels nearly 50 times those without. Samples comprised of sm...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.