In this work, the propulsion of a helical robot is experimentally characterized inside whole blood (in vitro model) and against the flowing streams of phosphate buffered saline (PBS) inside rabbit aorta (ex vivo model). The helical robot is magnetically actuated inside these models under the influence of rotating magnetic fields. The frequency response of the helical robot is characterized. Averaged speed is measured at actuation frequency of 8 Hz as 11.3 ± 0.52 (n = 5) and 7.45 ± 1.2 mm/s (n = 3) inside rabbit aorta and whole blood, respectively. The Speed of the robot inside rabbit aorta is characterized against flowing streams of PBS at flow rate of 90 ml/hr.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.