Abstract

Atmospheric non-thermal plasma has been widely used. The aims of this research are to characterize electrical properties and charge carrier mobility of corona discharge and dielectric barrier discharge (DBD) plasma reactor with multiple points to plane configuration. Plasma was generated by DC high voltage and a 2 mm glass plate used as dielectric barrier covers passive electrode surface. Plasma current and voltage were measured using an analog multimeter and oscilloscope. Charge carrier mobility was calculated using Sigmond’s unipolar saturation current modified with multiple points to plane approach. Experiment result showed that electric current is proportional to squared voltage, in accordance to unipolar saturation current. Charge carrier mobilities obtained for corona and DBD were in range of 1,66 – 7,18 cm2/V.s and 0,331 – 0,848 cm2/V.s, respectively. Charge carrier mobility in DBD reactor increases with increasing distance between electrodes. Maximum charge carrier mobility in corona discharge was obtained at a distance of 1 cm, while in DBD at 4 cm.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have