Abstract

The experimental devices ASDEX Upgrade (AUG) and Wendelstein 7‐X (W7‐X) are equipped with two neutral beam injectors each for plasma heating with up to 20MW. Four large titanium sublimation pumps (TSPs) (4×1.5×0.2m3) in each injector provide proper vacuum conditions (below 10−2Pa) during the 10s beam pulse with a gas feed of up to 30 Pa×m3/s. A maximum pumping speed of up to 3000m3/s for H2 is obtained by frequent renewal of the Ti coating at the pump surfaces. Ti is sublimed from 4m long ohmically heated hanging pairs of Ti sublimation wires. So far, all pairs of wires were operated with constant current during 120s, despite of the large spread of the resistance of the wires. Tests have been performed in a dedicated test facility in order to characterize the pumping performance for H2 with different parameters for sublimation power and time. The data gathered can be used to simulate fully operative TSP systems for real NBI operation scenarios in AUG and W7‐X, so as to find an optimal sublimation strategy for the TSPs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.