Abstract

3D NAND flash memory has entered dynamically into the space of enterprise server and storage systems, offering significantly higher capacity and better endurance than the latest 2D technology node. Moreover, the advancements in vertical stacking, cell design and program/read algorithms, have also enabled TLC 3D NAND flash with enterprise-level reliability, thus achieving further increase in capacity and cost-per-bit reduction. This paper presents an in-depth analysis of the bit-error characteristics of state-of-the-art 64-layer 3D TLC NAND flash with a focus on read-voltage calibration. We provide experimental measurements of the RBER and threshold voltage distributions using typical and mixed-mode test patterns of program/erase cycling, retention and read-disturb. Moreover, we quantify the RBER components attributed to threshold voltage level overlapping and on-chip 2-step program errors. Finally, we characterize how the optimal read voltages change under different device stress and we evaluate calibration schemes with different performance and complexity trade-offs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.