Abstract

Effect of arc voltage on different factor of design and control was investigated for high current in order to develop design guide of circuit breaker. In this study, dependences on these factors which are current, arc length, surface area on electrode and internal pressure of arc voltage were evaluated quantitatively. As a result of the evaluations, it was estimated that arc voltage near electrode surface rise linearly with arc current and the area on the surface to the power -0.8, and the voltage in arc column rise pressure increase to the power 0.3. We confirmed the validity of the characteristics of the estimated voltage by comparison with the generated voltage in an actual arc extinguishing chamber. The characteristics of the estimated voltage would be provided as effective guidelines to design arc extinguishing chambers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.