Abstract

Under ultra-low pressure, an electron beam is generated by the microwave electron cyclotron resonance plasma with a permanent magnet. By means of the Hall coil and Miller ampere meter, two electron current signals at the end of the extraction anode (Ia) and the sample holder (Is) were measured. The influences of discharge power, gas pressure, and accelerating voltage on the electron beam current Is were analyzed. The experimental results indicated that the extracted electron current can reach 75.1 mA at a gas pressure of 1.4 × 10-3 Pa, an accelerating voltage of 8 kV, and an orifice size of 3 mm in diameter. In order to estimate the focusing properties of the electron beam by the beam-focusing coil, the influence of the coil current on the size of the electron beam spot on the sample holder was presented and discussed. The intrinsic mechanism of electron beam extraction and propagation is revealed by numerical simulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.