Abstract

ABSTRACT In order to prevent flow blockage phenomenon and to reduce the impact of particles on the wall of the bend, an experimental study of the swirling flow pneumatic conveying system with a horizontal curved pipe was carried out in this work. The experiment was performed in a 90-deg pipe bend with pipe diameter 75 mm and centerline curvature ratio 12. The straight pipes with 75 mm inside diameter at the upstream and downstream of the bend were 1.3 m and 4.0 m in lengths, respectively. The initial swirl number was varied from 0.22 to 0.60, the mean air velocity from 10 to 20 m/s, and the solid mass flow rate from 0.07 to 0.68 kg/s. It is found that in the lower air velocity range, the overall pressure drop of the swirling flow pneumatic conveying shows a lower tendency than that of axial flow pneumatic conveying. The minimum air velocities can be decreased by using the swirling flow pneumatic conveying. From the visualization of particle flow patterns, the impact of particles on the wall of the bend can be reduced using the swirling flow.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.