Medium voltage in the electric power system of ship typically is powered by a large capacity transformer for low voltage electrical apparatus. When switching on, the primary side of transformer will produce very large current, which would endanger the safe operation of power for ships. The mechanism and characteristics of magnetizing inrush current is analyzed when the transformer switches with no load. We think that the reason caused magnetizing inrush current is transformers saturation. Pre-excitation is presented through a small volume transformer magnetizing method of suppressing the inrush current of transformer and validated by simulation and experiment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.