Abstract
The performance of a high voltage pulser in plasma immersion ion implantation is strongly influenced by the plasma load into which it operates. There are a number of plasma parameters, such as ion density, potential distribution and ionisation rate, that affect the formation of the cathodic sheath around the workpiece. In turn, these place limitations on the range of voltage, ion current density and duty cycle that is possible to achieve with the pulser. In this paper, we present results of studies into the performance of a 50 kV, 8 A pulser in the ANSTO PI 3 facility (∼ 0.4 m 3). The plasma is a low pressure radiofrequency discharge formed by 300 W of r.f. power at 13.56 MHz applied to a single-loop antenna immersed in a plasma with an ion density of approximately 10 9 cm −3 and filling pressure of 0.5–5 × 10 −3 mbar. The plasma parameters can be altered by varying the r.f. power, the plasma potential, the gas mixture and the filling pressure. Optical emission spectroscopy has shown a large increase in emission from atomic species that are sputtered from the surface of the workpiece during the high voltage pulse. This emission decays very rapidly when the high voltage pulse is terminated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.