Abstract

There are two major issues in the design of natural circulation systems (NCSs). One is to arrive at the maximum design power and the other is to ensure that the operating procedures and the operational transients do not lead to instability. The maximum design power depends on the critical heat flux (CHF) threshold and the stability threshold. If the CHF threshold is more than the Type II stability threshold, then the maximum power rating is stability-controlled. On the other hand, if the CHF threshold is below the Type II stability threshold, then the maximum power rating is CHF-controlled. There is also a third possibility that the maximum power is CHF-controlled for low inlet subcooling and stability-controlled for high inlet subcooling regions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.