Abstract

Background: Chronic kidney disease (CKD) is the 4 commonest cause of death in Nigeria. It affects the most economically productive age group. Many patients in stage 5 CKD are treated with haemodialysis which involves the movement of electrolytes and osmotic molecules from one body compartment to another, resulting in osmotic and anion-gap changes. These changes may be related to mortality in patients on haemodialysis. Objective: To determine the relationship of mortality to plasma osmolality and anion gap inpatients on haemodialysis. Methods: Fifty consecutive dialysis naive stable stage 5 chronic kidney disease subjects aged between 18 and 70 years, attending a Lagos Teaching Hospital were recruited. They were followed up from the salvage phase of 5 sessions carried out on alternate days through to the maintenance sessions of haemodialysis at a frequency of 2-3 times per week for six (6) months. Pre-and post-dialysis serum osmolality and anion gap were obtained for salvage and maintenance phases of haemodialysis. Results: Out of the 50 patients that started the study, 11 (22%) patients (9 males and 2 females) died while10 (20%) subjects (9 males and 1 female) were lost to follow-up before the commencement of the maintenance haemodialysis. Six more subjects (3 males and 3 females) withdrew from the study while 23(46%) entered the maintenance phase of the study. During the maintenance phase, 8(16%) (5 male and 3 female) subjects died while 15 subjects (30%) (9 males and 6 females) completed the study. The mean age of the subjects who completed the study was 46.2± 10.8years (46.9±9.4 years for the males and 45.4±12.1 years for the females).The mean age of the patients that died during maintenance haemodialysis was 46.6±10.9 years(46.1±12.0 years and 45.0±9.8 years for male and female respectively).The mean pre dialysis osmolality and anion gap during salvage haemodialysis were higher than the post dialysis values (298.15 ± 15 mOsm/kg vs. 276.0 ± 13.5 mOsm/kg, p=0.04 and 15.1 ± 3.3 vs. 13.6 ± 3.1, p=0.049).However, the mean pre and post dialysis osmolality and anion gap during maintenance haemodialysis sessions were similar [273.35±14.6 mOsm/kg vs. 270.60±13.0 mOsm/kg (p=0.065)and 12.7±2.9 vs. 12.2±3.2(p=0.059)].There was no significant difference in the pre- and post- dialysis osmolality and  anion gap of those that died and those that survived to the end of the study (p>0.10). Conclusion:  Changes in plasma osmolality and anion gapis not associated with increased mortality and hence may not be useful in predicting mortality during maintenance dialysis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call