Abstract

The IBA-Scanditronix NACP-02, IBA-Wellhöfer PPC-40 and PPC-05 plane-parallel ionization chambers have been simulated with the Monte Carlo code PENELOPE to obtain their chamber- and quality-dependent factors fc,Qo for a 60Co gamma beam. These are applicable to the determination of kQ beam-quality factors for the dosimetry of electron, protons and heavier charged particles beams based on standards of absorbed dose to water. The factor fc,Q is equivalent to the product sw,airp, but it is not subject to the assumed independence of perturbation factors and stopping power (Sempau et al 2004 Phys. Med. Biol. 49 4427–44). The calculations have been carried out using three different 60Co source models: a monoenergetic point source, a point source with a realistic 60Co spectrum and the simulated phase space from a radiotherapy 60Co unit. Both the detailed geometries of the ionization chambers and of the 60Co unit have been obtained from the manufacturers. In the case of the NACP-02 chamber, values of fc,Qo have been compared with those in the IAEA TRS-398 Code of Practice and from other authors, results being in excellent agreement. The PPC-05 and PPC-40 chambers are of relatively new design, and their values have not been calculated before. Within the estimated uncertainty, computed at the 2σ level (95% confidence limit), the results for each of the three chambers appear to be independent of the degree of sophistication of the 60Co source model used. For the NACP-02 chamber this assumption is justified by the excellent agreement between the various models, which occurs at the level of one standard uncertainty. This suggests the possibility of adopting the mean value of the three source models, weighted with the inverse of their corresponding uncertainties, as a better estimate of fc,Qo. A consequence of the above conclusions is that the estimated uncertainty of kQ beam-quality factors of all charged particles referred to 60Co can potentially be decreased considerably using our approach. For example, the estimated relative standard uncertainty of the denominator of kQ, given in TRS-398 as 1.6% for plane-parallel ionization chambers, can be reduced to 0.06% for a NACP chamber using the mean value of fc,Qo given in this work. Similar reductions could be obtained for the combined standard uncertainty of the kQ beam-quality factors of all charged particles, notably electrons.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.