Abstract

Keeping cool the lithium-ion battery improves its performance. In this study, focusing on battery cooling, a thermal control unit (TCU) containing metal fins was integrated into the battery. To boost TCU effectiveness, phase change material (PCM) was injected into it. By numerical solution, the temperature distribution in three areas of battery, fins and PCM was determined. Using Fourier's law, TCU heat dissipation to the environment was evaluated at different convection coefficients (5, 10, and 20 Wm2.K). It was observed that the presence of PCM is not always advantageous. The presence of PCM can only be useful if the PCM undergoes phase changes. This happened at 5 Wm2.K, and at best conditions, the battery temperature dropped by 8°C due to the PCM presence. After the melting process, the PCM presence significantly augmented the battery temperature. At 20 Wm2.K battery temperature was increased by 4.8 °C when PCM was loaded into TCU. Therefore, adding PCM to TCU with convection coefficient is not recommended. Increasing the number of fins declined the battery temperature. If the number of fins increases from three to five, the battery cooled by 1 to 1.7°C at convection coefficient range of 5–20 Wm2.K

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.