Abstract

To analyze the effect of the installation angle on the performance of axial flow fan, single blade model and whole model was established, steady flow in the axial flow fan of the 7500KW air-cooled motor was simulated by software FLUENT. Volume flow rate and hydraulic efficiency of the fan with different installation angle under specific outlet pressures were analyzed, the effect of different turbulence model on the numerical simulation results was discussed, and the effect of the single blade model, the whole model and lengthened flow passage model on the numerical calculation results was compared. The results show that the fan volume flow rate and hydraulic efficiency is higher with the installation angle of 30°, the results simulated by standard k-ε model are close to the results simulated by k-ω-SST model, calculation results of these three methods have a good agreement with each other, and the result coincides well with experimental measured values.