Abstract

AbstractIt is well known that helical ribbon (HR) impellers exhibit poor bottom pumping properties. Three different HR impeller geometries, varying in their bottom design, are compared in terms of their mixing performance. Particular emphasis is given to the improvement of pumping capabilities. The selected bottom geometries were a standard bottom termination, an anchor‐type termination and a paddle‐type termination. The investigation was based on the use of 3D finite‐element simulation to assess the hydrodynamics and mixing performance using various distributive and dispersive criteria. Analysis of Poincaré maps showed that an HR with a paddle‐type termination operating in a down‐pumping mode offered the best performance. Copyright © 2011 Curtin University of Technology and John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.