Abstract

INTRODUCTION: Near-infrared spectroscopy (NIRS) is a non-invasive and continuous monitor to measure the balance between cerebral oxygen delivery and consumption. So far no study has evaluated and compared the interaction between regional oxygen saturation (rSO2) values and cardiac function measured using both transesophageal echocardiography and the pulmonary artery catheter. We hypothesized that the evaluation of cardiac function with the transesophageal echocardiography (TEE) will correlate better with rSO2 values than through the measurements of cardiac performance obtained via a pulmonary artery catheter. METHODS: With approval of our Ethic and Research Committee, a retrospective analysis of a TEE database included consecutive patients undergoing various cardiac surgery between June 2002 and November 2004. Patients were selected if in addition to the TEE exam, cerebral oxygen saturation measured by NIRS during their anesthesia and a pulmonary artery catheter was used. Demographic data, preoperative medications and Parsonnet score, the nature of the surgery and preoperative comorbidities were collected. The TEE exam included the measurement of fractional area change (FAC) and the regional wall motion score index (RWMSI). Left ventricular diastolic function was evaluated according to published guidelines. Cardiac output (CO) was measured with thermodilution and stroke volume (SV) calculated by dividing the SV by the heart rate. Cardiac index (CI) and stroke volume index (SVI) obtained by dividing CO and SV by the body surface area. The echocardiographic exam and the hemodynamic profile were obtained after the induction of anesthesia and compared to the baseline NIRS value. T-test and chi-square were used to compare data according to their distribution. P<0.05 was considered significant. RESULTS: A total of 99 patients was included in the analysis. There were 65 men and 34 women. The mean age was 65±12.6 years old, Parsonnet score 18.0±12.7 and mean cerebral oxygen saturation values were 65.7±11.2 and 64.3±11.1, respectively on the left and right size. The mean FAC was 44.7±14.4%, RWMSI 1.3±0.5, cardiac index (CI) 1.9±0.4 L min-1 m-2 and stroke index (SI) 36.1±7.9 ml beat m-2. There was a significant positive correlation between left and right rSO2 values and the FAC (p<0.001 and p=0.0021), the RWMSI (p=0.0011 and p=0.0156), left ventricular diastolic dysfunction (p=0.0076 and p=0.003) but no correlation with CI and SI was observed. DISCUSSION: Our results indicate a better correlation between cerebral oxygen saturation values and the cardiac function evaluated by TEE compared to the hemodynamic values. This could be explained by an increase in cerebral oxygen extraction in patients with reduced cardiac function.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call