Abstract

ABSTRACT: One‐dimensional contaminant transport through a saturated soil is modeled using a 1.2‐m radius geotechnical centrifuge. Small‐scale physical modeling in the centrifuge is achieved in relatively short time, at stress distributions that are similar to those experienced in the prototype (actual site). A 0.05 mol/l of sodium chloride solution is used as a contaminant and conductivity cells measure the concentration of the contaminant throughout the porous medium. Scaling analysis for centrifuge modeling and 1‐g modeling are briefly discussed and it is concluded that centrifuge modeling simulates the effect of molecular diffusion; however, scaling of the effect of mechanical dispersion may be violated in the centrifuge if the interstitial fluid velocity is high. Centrifuge test results show good agreement with the predicted relationship between the coefficient of hydrodynamic dispersion and the Peclet number using column tests. Centrifuge modeling can be used as a complement of numerical modeling although the effect of mechanical dispersion may be overestimated in the former.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.