Abstract In the paper, a back swept impeller of centrifugal compressor is experimentally studied and numerically validated and modified to increase its pressure ratio and improve efficiency, as well as to analyse the effect of splitter blade location between two main blades. The back swept multi splitter blade impeller was designed with a big splitter positioned close to the main blade suction surface and a smaller splitter close to the pressure surface. Adding this multi splitter improves the overall performance of the modified impeller due to less intensive flow separation and smaller pressure loss. In particular, the total pressure ratio was observed to increase from 4.1 to 4.4, with one percent increase in efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.