Abstract

Simulated body fluid (SBF) solutions are widely used for in vitro bioactivity tests and to coat bioinert materials with biomimetic calcium phosphates. In this study SBF solutions with varying HCO3 - content were used to precipitate hydroxy carbonated apatite (HCA) on a bioactive titanium surface. XRD as well as cross-sectional TEM analyses revealed that the biomimetically derived crystallites show a preferred growth orientation in direction of their c-axis and perpendicular to the surface of the substrate. FTIR and Raman analyses revealed that, as long as the HCO3 - concentration in the testing solutions is below 20 mmol/l, only B-type HCA precipitates. Using SBF with a HCO3 - concentration equal to human blood plasma (27 mmol/l) leads to a AB-type substitution where, in accordance with bone mineral, CO3 2- substitutes PO4 3- as well as OH-.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.