Abstract
A lightweight carbon-phenolic ablator, with a density of 0.5g/cm3, designed to be used as a thermal protection system for a re-entry space vehicle, was manufactured by infiltration of a carbon felt with a phenolic resin. A sample of this ablative material was tested in a Plasma Wind Tunnel (PWT) facility, simulating erosion and heat flux conditions consistent with an orbital reentry. The surface temperature of the test article was monitored during the PWT test. Microstructural and microtomographic analyses were carried out on the tested sample to investigate the effect of the high heat flux exposure on the composite material, by measuring the amount of ablation and the depth of pyrolyzation. Moreover a finite element model was implemented in order to rebuild the PWT test. Very encouraging results were obtained in terms of surface insulation capacity and surface recession. The pyrolysis and erosion of the ablator was simulated by implementing a complex finite element model, with results in very good agreement with experimental evidences.