Abstract

The in-plane and in-depth thermal conductivities of epoxy-carbon fiber composites have been measured at 77 K and 300 K. The experimental technique rests on the hot disk method. The two thermal conductivities as well as the thermal contact resistance between the probe and the composite materials are estimated from measurement data and an analytical heat transfer model within the experimental configuration. The results obtained at 77 K explained well the ignition test results performed on the composites at 77 K with regards to liquid oxygen storage.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.