Abstract

A method utilizing capillary-channeled polymer (C-CP) fibers as stationary phases in high-performance liquid chromatographic separations has been investigated. Polymeric fibers of differing backbones (polypropylene and polyester) having nominal diameters of ∼50 and ∼35 μm and a channeled structure on their periphery were packed into stainless steel tubing (305×4.6 mm I.D.) for use in reversed-phase separations of various mixtures. The fibers have eight channels running continuously along the axis which exhibit very high surface activity. As such, solvent transport is affected through the channels through wicking action. Bundles of 1000–3000 fibers are loaded co-linearly into the tubing, providing flow channels extending the entire length of the columns. As a result, backing pressures are significantly lowered (∼50% reduction) in comparison to packed-sphere columns. In addition, the capital costs of the fiber material (<US$0.25 per column) are very attractive. Flow-rates of up to 5 ml/min can be used to achieve near baseline separation of related compounds in reasonable run times, indicating very fast mobile phase mass transfer (C-terms). The polymer stationary phases demonstrate high selectivity for a wide variety of analytes with gradient elution employed successfully in many instances. Specifically, separations of three polyaromatic hydrocarbons (benzo[ a]pyrene, chrysene, pyrene), mixtures of both organic and inorganic lead compounds [chlorotriethyllead, chlorotriphenyllead, lead nitrate, lead(II) phthalocyanine], and a lipid standard of triglycerides were accomplished on the polymeric stationary phases. Other species of biological interest, including groups of aliphatic and aromatic amino acids have also been effectively separated. The reversed-phase nature of the fiber surfaces is supported through atomic force microscopy measurements using hydrophilic and hydrophobic functionalized polystyrene beads as the probe tips. Separations of the various analytes demonstrate the feasibility of utilizing C-CP fibers as stationary phases in reversed-phase LC. It is envisioned that columns of this nature would be particularly useful in prep-scale separations as well as for immobilization matrices for organic constituents in aqueous environments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.