Abstract

A sensitive and selective gas chromatographic—electron-capture assay was developed for the determination of the aldose reductase inhibitor imirestat in lens and plasma. The method involves solid-phase extraction of drug and internal standard from the plasma specimen or lens sample homogenate using “Baker”-10 SPE™ extraction columns followed by derivatization with pentafluorobenzyl bromide and further purification. Derivatives of drug and internal standard were separated on a fused-silica capillary column and analyzed using a 63Ni electron-capture detector. The limit of detection was 2.5 ng per lens or ml of plasma. The method was used to evaluate the pharmacokinetics of imirestat in human subjects and to quantitate imirestat in animal lens tissue following topical ocular administration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.