Abstract

Hypothermic machine perfusion (HMP) reduces renal injury in donation after circulatory death donors with a high Kidney Donor Profile Index (KDPI). This study aims to characterize the correlation between KDPI, HMP parameters, and donor vitals during the withdrawal period in predicting short- and long-term graft outcomes. ANOVA with Tukey's honestly significant difference tests compared the relationship between average flow, average resistance, peak resistance, flow slope, and resistance slope on day 30, 1-y, and 3-y eGFR, and days of delayed graft function. Graft and recipient survival rates were assessed using Kaplan-Meier analysis. The data for 72 grafts were suitable for analysis. Kidneys with KDPI >50% had a significantly higher day 30, and 1-y posttransplant eGFR, if HMP average flow was >150 mL/min, or the average resistance was <0.15 mm Hg/mL/min, compared with kidneys with also KDPI >50% but had not achieved the same pump parameters. There were no significant differences in the Kaplan-Meier analysis, considering recipient or graft survival, regardless of the KPDI score with 3- or 5-y outcomes. Use of average resistance and average flow from a HMP, in conjunction with KDPI, may be predictive of the short- and long-term function of donation after circulatory death kidney transplants.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call