Abstract

This study aimed to evaluate polylactic acid (PLA) as a provisional crown material. Lower right first molar phantom tooth was used for the fabrication of 60 crowns. Samples were divided into three groups (n=20) according to the material: Group PL (PLA), Group PM (polymethyl methacrylate), and Group PE (polyetheretherketone). Each group was investigated for internal and marginal fit, fracture strength, and fracture mode. Data were analyzed using ANOVA, chi-squared test, and Tukey's tests (p≤0.05). The average marginal gap value of each group was: PE 56.00±4.67 µm, PM 61.15±4.44 µm, and PL 60.40±2.85 µm (p<0.001). The average internal gap value for each group was: PE 128.90±8.39 µm, PM 132.40±7.51 µm, and PL 130.75±9.76 µm (p=0.442). The average fracture strength of each group was: PE 840.90±13.23 N, PM 733.30±9.00 N, and PL 664.50±10.79 N (p<0.001). Results demonstrated that PLA may be a good option as a provisional crown material.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.