Abstract

Triolein embedded cellulose acetate membrane (TECAM) passive samplers provide potentially powerful tool for monitoring time weighted average concentrations (CTWA) of trace hydrophobic organic contaminants in water. To study the field performance of TECAM, exchange kinetics of chemicals between water and TECAM were studied at different temperature and water flow rates. Results showed that the uptake rate constant (ku) in TECAM was less sensitive to temperature variation than the SPMD and Chemcatcher. The ku in TECAM was sensitive to even a slight change of the flow rate, which required the field calibration using performance reference compounds (PRCs). To estimate CTWA by TECAM, both empirical model and WBL model were compared in laboratory conditions, and only small differences were observed between the predicted and measured ku. Field validation was conducted to test the sampler performance alongside spot sampling. A good agreement of water concentration was obtained by the two sampling techniques.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.