Abstract

Calculated results are presented for a variety of neutron spectra incident on a tissue‐equivalent phantom. The neutron spectra considered are those produced by 35‐ and 50‐MeV deuterons in a thick beryllium target and by 67‐MeV protons in a thick lithium target. Results are presented for the absorbed doses, LET spectra, cell‐survival probabilities, OERs, and RBEs as a function of position in the phantom. The cell‐inactivation calculations were carried out using the model of Katz et al. and parameters for T‐1 kidney cells. In the case of incident neutrons from 35‐MeV 2H on Be, experimental and calculated absorbed‐dose data are compared as a function of position in the phantom and are shown to be in good agreement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.