Abstract
AP1000 nuclear power plant model is founded via RELAP5/mod 3.3 program in detail. Refer to SGTR accident basic assumptions in the safety analysis report, calculations for AP1000 nuclear power plant SGTR accident are carried out. And through comparison between the result got and the result from safety analysis report calculated by LOFTTR2 program, the two results are very consistent. It's found that even if the operators do not interfere, AP1000 nuclear power plant protection systems and passive design measures will trigger an automatic response measures, it can terminate the SG heat transfer tube leaking and make RCS be stable in a safe condition and to prevent SG overflowing and ADS actions occurring.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Computational Methods in Sciences and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.