Abstract

ABSTRACTThe problem of deriving a formula to calculate sterilizing values from temperature curves was examined. For the high sterilizing value range (U/f>1), a simple algebraic formula was found that enabled the temperature approach g and the sterilizing value U to be calculated from each other to within 3%. For low sterilizing values (U/f>1) regression equations were presented to calculate g from U. A table was also given as an alternative to the equations. The method took into account variations in initial product temperature and cooling water temperature. Being expressed in terms of dimensionless quantities, it was more generally applicable than previous methods derived along similar lines.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.