Abstract

In modern electric vehicles, electrical failure has become a critical problem that reduces the lifetime of traction motors. Moreover, traction motors with high-voltage and high-speed systems for a high power density have been aggravating the shaft voltage problems. This study identifies that direct-oil-cooling systems exacerbate this problem. To address this, an analytical method for calculating parasitic capacitance is proposed to determine the effects of cooling oil in a traction motor with a direct-oil-cooling system. Capacitance equivalent circuits are configured based on whether the slot is submerged in the cooling oil. In addition, an electric field decomposition method is applied to analyze the distortion of the electric field by the structure of the conduction parts in the motor. The results indicate that the parasitic capacitances of the traction motor are increased by the influence of the cooling oil resulting in an increase in the shaft voltage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.