Abstract

In this paper, we consider the model of engineering calculation for the matching of the explosive-magnetic generators (EMG) and pulsed plasma accelerator (PPA) at amplitudes of currents reaching 2.5 MA. The main features of the model are taking into account the dynamics of change in the inductance of PPA and the using of the concentrated mass approximation for the current shell. The taken assumptions were checked by experimental data on real PPA powered by EMG. It is shown that the built model has sufficient accuracy for preliminary calculations for design and installation of such technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.