Abstract
Fuel-NOx concentrations under the conditions of high CO_2 concentration have been experimentally investigated with a tubular flame burner. At first, flame stability limits are examined for CH_4/O_2/CO_2 mixture with a flat flame burner as well as a tubular flame burner. Results show that, for CO_2-dilution mixture, a flame can be established on a flat flame burner when O_2 concentration in oxidizer is greater than 26%. On the other hand, a tubular flame can be established in wide range of φ even O_2 concentration in oxidizer is 21% O_2. The results of NOx measurement showed that the Fuel-NOx concentration large for lean to stoichiometric condition. The results also showed that the Fuel-NOx concentration of 32% O_2 CO_2-diluted mixture is almost identical with that of air combustion, and NOx concentration drastically decreases with decreasing oxygen concentration in oxidizer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Proceedings of the Thermal Engineering Conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.